DEVICE: Trilogy Transcatheter Heart Valve (00850000898103)
Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to
GUDIDSupport@fda.hhs.gov.
Device Identifier (DI) Information
Trilogy Transcatheter Heart Valve
TRILOGY-THV-S
In Commercial Distribution
TRILOGY-THV-S
Jenavalve Technology, Inc.
TRILOGY-THV-S
In Commercial Distribution
TRILOGY-THV-S
Jenavalve Technology, Inc.
Pericardial THV Size 23MM
Device Characteristics
| MR Conditional | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| Yes |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 60245 | Aortic transcatheter heart valve bioprosthesis, stent-like framework |
An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed and/or regurgitant aortic heart valve, or previously-implanted aortic heart valve prosthesis, and which is designed to be implanted with a catheter via transarterial access (e.g., femoral, subclavian, aortic) or transapical access while the heart is beating. It is comprised of the xenograft, processed to render the tissue non-viable, attached to an expandable metal framework, which is implanted with an included catheter, and when in situ, may be expanded with a balloon or self-expand. Typically devices associated with implantation (e.g., catheter, introducer) are included.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| NPT | Aortic Valve, Prosthesis, Percutaneously Delivered |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Special Storage Condition, Specify: These devices must be stored in a cool, dry place. Store the valve (THV) in the upright position. The THV must be stored between 2°C (36°F) and 25°C (77°F). |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: 23MM |
Device Record Status
447c8b21-dbba-4e5e-a5fd-a9853972a406
May 19, 2026
2
March 25, 2026
May 19, 2026
2
March 25, 2026
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1-866-588-8287
CustomerSupport.US@jenavalve.com