DEVICE: InferRead CT Stroke.AI (00850003095011)
Device Identifier (DI) Information
InferRead CT Stroke.AI
1.1.0.0
In Commercial Distribution
Infervision US Inc
1.1.0.0
In Commercial Distribution
Infervision US Inc
InferRead CT Stroke.AI is a radiological computer aided triage and notification software for use in the analysis of non-enhanced head CT images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging suspected positive findings of intracranial hemorrhage (ICH).
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
40935 | Diagnostic x-ray digital imaging system workstation |
A freestanding component of an x-ray-based diagnostic digital imaging assembly [e.g., a digital x-ray system, x-ray computed tomography (CT) system, or fluoroscopy system] designed to process patient radiological images; it may additionally be intended to be integrated as part of a radiology picture archiving and communication system (PACS). It consists of dedicated hardware (e.g., computer processing unit, monitor) with integrated software typically to assist image analysis (e.g., viewing, manipulation, interpretation); it does not include controls for direct operation of the imaging system.
|
Active | false |
63386 | X-ray image interpretive software |
An interpretive software program intended to be used to analyse non-dental x-ray images (e.g., chest, mammograms, tomograms) to detect and localize suspected abnormalities (e.g., tumours, emphysema, tuberculosis, blunted costophrenic angle) and possibly provide results as clinically relevant tags. It typically utilizes artificial intelligence (AI) and deep learning techniques, and may be compatible with radiology information systems, data formats, and medical imaging software programs [e.g., picture archiving and communication system (PACS), digital imaging and communications in medicine (DICOM) format].
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
QAS | Radiological Computer-Assisted Triage And Notification Software |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K211179 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
2db679d5-9fbe-403d-9286-3997c0298c17
August 26, 2021
1
August 18, 2021
August 26, 2021
1
August 18, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined