DEVICE: Balance Advantage Computerized Dynamic Posturography System (00850017250079)

Device Identifier (DI) Information

Balance Advantage Computerized Dynamic Posturography System
97P-0036
In Commercial Distribution

BERTEC CORPORATION
00850017250079
GS1

1
619142540 *Terms of Use
The Computerized Dynamic Posturography (CDP ) system is a clinical balance assessment device that collects and analyzes force and moment data from a balance plate. The balance plate is seated in a dynamic chassis that can move in both translational and rotational directions, under control of the Balance Advantage (BA) software program. The BA software contains both assessment and training modules that can be used during each session. Assessments have set run-times during which they collect data after the “Start” button is pressed, while trainings have customizable run-times varying from 1 minute to 15 minutes. The system is intended to be used by trained clinicians in a hospital or clinical (physical therapy or ENT) environment who operate the software and ensure the safety of the patient. The patient being assessed on the system is placed in a harness. There are three different harness sizes with varying weight limits that can be purchase with the system; standard harness supports up to 300lbs, pediatric is up to 100lbs, and the bariatric supports up to 450lbs. The mechanical components of the system are designed to support up to 500lb patients.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
43114 Posturography system platform
A device that is a component of a balance/mobility management system equipped with built-in sensors, transducer and/or force plates that register movement of the patient when he/she adjusts his/her centre of gravity (COG) alignment according to the doctor's instructions, or, the platform provokes destabilizing perturbations and the output of these movements are measured and recorded to the system computer. It is used, e.g., for motor control test (MCT), posture studies, balance, mobility training, and/or sense of equilibrium studies. The patient will stand on this device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KHX Platform, Force-Measuring
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

a73ae03c-bef2-41c4-b738-5c50b25cab6e
January 13, 2021
1
January 05, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
1-614-543-8099
support@bertec.com
CLOSE