DEVICE: NIRA PRO (00850020752119)

Device Identifier (DI) Information

NIRA PRO
151-000
In Commercial Distribution

Nira Innovations Incorporated
00850020752119
GS1
April 13, 2030
1
079208137 *Terms of Use
The NIRA PRO is a hand-held reusable OTC non-fractional diode laser device employing 1450 nm wavelength. The NIRA PRO consists of a hand piece, wall-plug battery charger, and 1.5 foot USB cable. The hand piece fits in the hand and the laser light comes out of the tip. There is a USB C connector interface that provides battery charging. The NIRA PRO is used for treatment of periorbital wrinkles.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
Yes
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
45221 Dermatological laser beam guiding handpiece
A hand-held component of a dermatological laser system designed to conduct a therapeutic laser (e.g., solid state laser) from the laser generator to the treatment site for ablative and non-ablative treatment of the skin (e.g., removal of pigment/vascular lesions, scarring, wrinkles, tattoos, hair, and skin resurfacing and rejuvenation). This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OHS Light Based Over The Counter Wrinkle Reduction
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K222685 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal
Storage Environment Humidity: between 10 and 100 Percent (%) Relative Humidity
Storage Environment Temperature: between -20 and 35 Degrees Celsius
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Temperature: between 15 and 35 Degrees Celsius
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d756139a-731d-428e-bf68-24029fd20c7c
December 30, 2024
3
July 14, 2023
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE