DEVICE: iLet Starter Kit - Inset 23" (00850050080084)

Device Identifier (DI) Information

iLet Starter Kit - Inset 23"
Insulin Only
In Commercial Distribution
BB1005
Beta Bionics, Inc.
00850050080084
GS1

1
835742136 *Terms of Use
iLet Bionic Pancreas Starter Kit with consumables (Pharmacy Starter Kit)
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60770 Ambulatory insulin infusion pump/interstitial glucose monitoring system
An assembly of portable devices intended to simultaneously continuously monitor interstitial glucose levels and subcutaneously infuse insulin in patients with diabetes. Sometimes referred to as a closed loop artificial pancreas, it consists of a percutaneous blood glucose monitoring system (CGM), an ambulatory insulin infusion pump, and software on a dedicated handset or transmitter capable of telemetric communication with the other components. The software contains an algorithm to allow continuous communication between the two devices, and may enable the manual input of data with respect to meals and physical activity.
Active false
35833 Electric infusion pump administration set, single-use
A collection of sterile devices (e.g., plastic tubing, check valve, roller clamp, Y-site connector, Luer, needle/catheter) intended to be used in combination with an electrically-powered infusion pump for the intravenous (IV), subcutaneous, intramuscular, or epidural administration of medication. This is a single-use device.
Active false
35838 Ambulatory insulin infusion pump reservoir
An insulin-filled receptacle (e.g., a cartridge similar to a syringe) intended to be used together with a body-worn insulin pump for the delivery of patient-controlled amounts of insulin to an ambulatory diabetic. This is a single-use device.
Active false
47017 General-purpose syringe, single-use
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended for various medical applications and is not dedicated to medication administration. At the distal end of the barrel is a male connector (typically Luer-lock/slip type) for the attachment to a hypodermic needle or an administration set. It is typically made of plastic and silicone materials and may have anti-stick plunger allowing smooth plunger movement, either manually or by a syringe pump. This is a single-use device.
Active false
59230 Hypodermic needle, single-use
A non-dedicated, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a noninvasive device (e.g., syringe, secondary medication set) to administer and/or withdraw (aspirate) fluids/drugs; it may also be used for fluid/drug preparation. Some types are designed with a shielding mechanism (e.g., safety cap) for protection from sharp injuries. It is not specifically designed for blood collection or artery puncture, and does not have wings for fixation/placement (i.e., not a blood collection, intra-arterial, or venous butterfly needle). This is a single-use device.
Active false
60538 Luer/Luer linear connector, single-use
A small, non-powered, noninvasive tubular, two-way/linear connector with a Luer connection (either lock or slip) at both ends intended to connect two luminal devices (e.g., catheter, tubing, container) with each other. It may have a straight or elbow shape; it does not incorporate a filter, valve, clamp, tubing nor puncturing component. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QJI Interoperable Automated Glycemic Controller
QFG Alternate Controller Enabled Insulin Infusion Pump
FPA Set, Administration, Intravascular
FMF Syringe, Piston
FMI Needle, Hypodermic, Single Lumen
JKA Tubes, Vials, Systems, Serum Separators, Blood Collection
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d1365103-15c8-4efe-b958-76c2e9539cc5
November 21, 2024
1
November 13, 2024
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
Yes
Yes
No CLOSE

Customer Contact

[?]
855-745-3800
xx@xx.xx