Device Identifier (DI) Information
CrossRoads Screw System
3.0 Headed Implant Prep Kit Including Reamer
In Commercial Distribution
1456-3030
CROSSROADS EXTREMITY SYSTEMS
3.0 Headed Implant Prep Kit Including Reamer
In Commercial Distribution
1456-3030
CROSSROADS EXTREMITY SYSTEMS
The CrossRoads Screw System is indicated for fracture repair and fixation, osteotomy, joint fusion, reconstruction and arthrodesis of bones appropriate for the size of the device.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
58796 | Surgical depth gauge, single-use |
A surgical instrument designed to measure the depth of a recess, usually to measure the depth of holes being drilled in bone to determine the length of the bone screw to be used. It may take the form of: 1) a device with a moveable (sliding) centrepiece (a prong), the tip of which is inserted into the recess to read from a scale; 2) a circular disc with a central hole which is clipped to a drill bit so that the device slides up as the drill bit is advanced; or 3) a cylindrical rod with markings. This is a single-use device.
|
Active | false |
58776 | Surgical screwdriver, single-use |
A non-powered tool that fits into a screw head in order to apply rotation to tighten/loosen/remove a screw during a surgical procedure. It typically has a high-grade stainless steel shaft with a distal end dedicated to fit into a screw head that may be slotted, Phillips (cross head), Pozidriv (Supadriv), Torx, Hex (Allen), Robertson (square), spanner head (twin pins), Polydrive, or one-way (clutch). The proximal end of the shaft may have a handle for manual use, or it may have a profiled tang that fits into an interchangeable screwdriver handle, a manually-operated chuck, or a power driver. This is a single-use device.
|
Active | false |
47634 | Surgical countersink, single-use |
A rotary surgical instrument designed to enlarge the diameter of the proximal portion of a hole drilled in bone. It is a shaft of metal with a cutting head, available in various configurations, that is rotated at low speeds typically by a drilling system. The device is typically used to recess the head of a screw/bolt within bone (enable it to lie flush with or below the bone surface) or to help accommodate the implantation of a device in bone. This is a single-use device intended to be sterilized prior to use.
|
Active | false |
47829 | Surgical instrument handle, non-torque-limiting |
A hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, such as manual rotation of a bone screw or reamer; it does not include a torque-limiting function. The device is typically made of metal and/or synthetic material and may have a straight or T-shaped handle grip which may include additional features such as a ratchet mechanism to allow the surgeon to maintain a constant hold on the handle when providing rotation in one direction. This is a reusable device.
|
Active | false |
43390 | Fluted surgical drill bit, single-use |
A shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a double-edged cutting head that is formed from two spiralled flutes that extend the length of the insertion part of the drill. At the proximal end, it is mounted into a surgical power tool or a surgical hand drill/brace. This is a single-use device.
|
Active | false |
66935 | Orthopaedic intraoperative positioning pin, single-use |
A nonimplantable device in the form of a thin rod intended to be drilled into bone to assist with the positioning of an implantable device and/or surgical instrument (e.g., fixation plate, drill guide) during an orthopaedic procedure. It is also referred to as a wire or temporary K-wire. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LXH | Orthopedic Manual Surgical Instrument |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
182b7955-c999-45c4-8cf0-7d33b3416c41
March 21, 2025
12
March 07, 2016
March 21, 2025
12
March 07, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found