DEVICE: ActaStim-S (00850372007189)

Device Identifier (DI) Information

ActaStim-S
1101-0007
In Commercial Distribution
1101-0007
THERAGEN, LLC
00850372007189
GS1

1
080028759 *Terms of Use
ActaStim-S Spine Fusion Stimulator - Leadwire, Long
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35463 Patient-worn bone growth electromagnetic stimulator
A battery-powered, body-worn device designed to apply an electrical stimulus directly to bone to promote bone formation (i.e., osteogenesis). It is intended to generate an electromagnetic (EM) field (and its associated induced voltage effects) around a fracture or fusion site; it is not intended to apply an electric current directly to the body. The device is used as an alternative to bone grafting for non-union fractures (a condition in which the ends of a fractured bone fail to unite), and as a spinal fusion adjunct in treating degenerative vertebral diseases. It is also known as an osteogenesis stimulator.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LOF Stimulator, Bone Growth, Non-Invasive
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P190030 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 5 and 40 Degrees Celsius
Storage Environment Temperature: between 5 and 40 Degrees Celsius
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Storage Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 700 and 1060 millibar
Storage Environment Atmospheric Pressure: between 700 and 1060 millibar
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

eac6da4c-759f-426f-9581-7763adf72b17
February 16, 2021
1
February 08, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
No
No
No
No CLOSE

Customer Contact

[?]
1-800-901-5667
help@actastim.com
CLOSE