DEVICE: Wildcat (00851354004004)

Device Identifier (DI) Information

Wildcat
W400
In Commercial Distribution
W400
AVINGER, INC.
00851354004004
GS1

1
003152968 *Terms of Use
"The Wildcat CTO Catheter is intended to create a channel in totally occluded peripheral vessels. The device may also be used to faciliate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature. The Wildcat Catheter is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast.The Wildcat CTO Catheter is a 6F sheath and 0.035"" guidewire compatible over-the-wire device. It consists of a catheter shaft with a handle assembly at the porximal end and an atraumatic Distal Tip. A locking Luer connector at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only. At the Slider’s most proximal location, the Wedges are in the retracted position. At the mid-point location, the Wedges are deployed. Moving the slider distal from this point initiates deflection of the Distal Tip. The amount of tip deflection increases with distal movement of the slider. At the most distal location, the Wedges remain fully deployed and the Distal Tip is at maximum deflection. The deployment and retraction of the Wedges as well as the deflection of the Distal Tip is visible under fluoroscopic guidance.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
44307 Mechanical atherectomy system catheter, peripheral
A sterile, flexible tube (catheter) intended to be percutaneously introduced for the intraluminal mechanical disruption of atheroma plaque from the walls of peripheral arteries. It has a power-driven cutting or abrasive head for slicing/grinding the atheroma into fragments small enough to be aspirated or absorbed. This device is not intended for use in the coronary, carotid, iliac or renal vasculature. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQY Catheter, Percutaneous
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
Yes
Sterilization Method [?]
Radiation Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

8314c5bb-9f03-4596-962c-ee2538c5e907
March 29, 2019
1
March 21, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
Yes
Yes
No CLOSE

Customer Contact

[?]
650-241-7030
tlawson@avinger.com