"Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance.
The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire.
Kittycat 2 is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Kittycat 2 Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
Kittycat 2 is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast."
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44307 | Mechanical atherectomy system catheter, peripheral |
A sterile, flexible tube (catheter) intended to be percutaneously introduced for the intraluminal mechanical disruption of atheroma plaque from the walls of peripheral arteries. It has a power-driven cutting or abrasive head for slicing/grinding the atheroma into fragments small enough to be aspirated or absorbed. This device is not intended for use in the coronary, carotid, iliac or renal vasculature. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQY | Catheter, Percutaneous |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
b02c93f8-772b-4c0c-85b2-f13e40ed1aaa
March 29, 2019
1
March 21, 2019
March 29, 2019
1
March 21, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
650-241-7030
tlawson@avinger.com
tlawson@avinger.com