DEVICE: Ocelot PIXL (00851354004141)
Device Identifier (DI) Information
Ocelot PIXL
P135
In Commercial Distribution
P135
AVINGER, INC.
P135
In Commercial Distribution
P135
AVINGER, INC.
"The Ocelot PIXL System consists of the Ocelot PIXL Catheter (“Ocelot PIXL”), the Lightbox console (“Lightbox”), and the Lightbox Umbilical (“Umbilical”). This system combines the use of Avinger’s peripheral catheter designs and an Optical Coherence Tomography (OCT) intravascular orientation and imaging tool. The Ocelot PIXL System is intended to cross chronic total occlusions in the peripheral vasculature while simultaneously providing OCT visualization to help orient the distal tip of the Ocelot PIXL to support the primary intended use.
Use of Ocelot PIXL in conjunction with Lightbox allows for OCT imaging as an adjunct to fluoroscopy which facilitates intravascular orientation of the catheter. See Lightbox Operator’s Manual and Umbilical IFU for guidance on setting up and using the Lightbox and Umbilical, respectively. Ocelot PIXL is available in 2 different lengths, 135cm working length and 150cm working length.Ocelot PIXL is an over-the-wire device compatible with a 5F sheath and 0.014” guidewire. It consists of a catheter shaft with handle assembly at the proximal end and a distal tip designed to cross CTOs. A locking luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire (i.e., Lumen Flush Port). The catheter is sterilized by ethylene oxide and is intended for single use only. "
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44307 | Mechanical atherectomy system catheter, peripheral |
A sterile, flexible tube (catheter) intended to be percutaneously introduced for the intraluminal mechanical disruption of atheroma plaque from the walls of peripheral arteries. It has a power-driven cutting or abrasive head for slicing/grinding the atheroma into fragments small enough to be aspirated or absorbed. This device is not intended for use in the coronary, carotid, iliac or renal vasculature. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
PDU | Catheter For Crossing Total Occlusions |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K123532 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3966087a-a15b-44f0-a3b3-56a80e06d26b
March 29, 2019
1
March 21, 2019
March 29, 2019
1
March 21, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
650-241-7030
tlawson@avinger.com
tlawson@avinger.com