DEVICE: Vanguard (00851616007385)

Device Identifier (DI) Information

Vanguard
6080x135
In Commercial Distribution
V1-6080-135-01
Contego Medical, Inc.
00851616007385
GS1

1
048268128 *Terms of Use
The Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection is indicated for percutaneous transluminal angioplasty (PTA) and capture and removal of embolic material during angioplasty, for the femoral, iliac, popliteal and profunda arteries. The System is not intended for use in the renal, cerebral, coronary or carotid vasculature.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
17184 Peripheral angioplasty balloon catheter, basic
A sterile, non-drug-eluting, flexible tube designed for percutaneous transluminal angioplasty (PTA) to dilate a stenotic peripheral (i.e., non-cerebral, non-coronary) artery by controlled inflation of a distensible balloon(s) at its distal tip; it may also be intended for positioning and expansion of a stent/stent-graft. It is available as an over-the-wire (OTW) type with multiple lumens, or a rapid exchange (RX) type with a single lumen. Some types may include cutting/scoring elements (e.g., microsurgical blades, dual wire configurations) to score/modify the plaque. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LIT Catheter, Angioplasty, Peripheral, Transluminal
NTE Temporary Carotid Catheter For Embolic Capture
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K181529 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

4b279b99-0ffd-4505-86fe-56b8d0886f5e
September 13, 2023
1
September 05, 2023
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
+1-919-459-7250
info@contegomedical.com
+1-800-708-7271
info@contegomedical.com
CLOSE