DEVICE: Neuroguard IEP® System (00851616007606)
Device Identifier (DI) Information
Neuroguard IEP® System
NG-0730-140-2
In Commercial Distribution
NG-0730-140-2
Contego Medical, Inc.
NG-0730-140-2
In Commercial Distribution
NG-0730-140-2
Contego Medical, Inc.
The Neuroguard IEP System consists of three main components:
• A self-expanding nitinol stent
• A delivery catheter which includes a post-dilation balloon and activation handle
• Embolic protection filter that is integrated at the distal end of the delivery system
Device Characteristics
MR Conditional | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45851 | Bare-metal carotid artery stent |
A non-bioabsorbable tubular device dedicated to implantation in a carotid artery to maintain arterial patency and improve luminal diameter in patients with atherosclerotic disease. It is made of metal [e.g., nickel-titanium alloy (Nitinol)] typically in a tubular mesh structure, and is typically delivered to the site of implantation by a dedicated instrument where it self-expands upon release. It is available in a variety of lengths and diameters and may be used in conjunction with an embolic protection device. Disposable devices associated with implantation may be included.
|
Active | true |
58112 | Carotid artery embolic protection system |
An assembly of devices intended to provide cerebrovascular embolic protection during carotid artery angioplasty and stenting procedures. It is available in various configurations and typically includes a sheath/catheter(s), intravascular balloon(s), guidewire, and extracorporeal valves/filters. The assembly is introduced into an artery percutaneously and used to produce blockage of blood through balloon inflation, typically at the carotid bifurcation and internal carotid artery to prevent distal embolization by particulate debris/thrombus and allow removal of debris/thrombus by blood filtration or aspiration. This is a single-use device.
|
Active | false |
17184 | Peripheral angioplasty balloon catheter, basic |
A sterile, non-drug-eluting, flexible tube designed for percutaneous transluminal angioplasty (PTA) to dilate a stenotic peripheral (i.e., non-cerebral, non-coronary) artery by controlled inflation of a distensible balloon(s) at its distal tip; it may also be intended for positioning and expansion of a stent/stent-graft. It is available as an over-the-wire (OTW) type with multiple lumens, or a rapid exchange (RX) type with a single lumen. Some types may include cutting/scoring elements (e.g., microsurgical blades, dual wire configurations) to score/modify the plaque. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NIM | Stent, Carotid |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
P240009 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
b44b324c-f5e5-4ad9-9d57-79cf6c8b3480
October 31, 2024
1
October 23, 2024
October 31, 2024
1
October 23, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1-800-708-7271
info@contegomedical.com
info@contegomedical.com