DEVICE: On-X Aortic Heart Valve with Conform-X Sewing Ring and Extended Holder (00851788001464)

Device Identifier (DI) Information

On-X Aortic Heart Valve with Conform-X Sewing Ring and Extended Holder
ONXACE-23
In Commercial Distribution

ON-X LIFE TECHNOLOGIES, INC.
00851788001464
GS1

1
844782318 *Terms of Use
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position. The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity. The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation. The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only. Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60240 Aortic bi-leaflet mechanical heart valve prosthesis
An artificial substitute for a natural aortic heart valve intended to be implanted during open heart surgery typically to treat acquired or congenital valvular disease. It consists of two flat, semicircular, pyrolytic carbon-coated or polymer leaflets that pivot about pyrolytic carbon or metal struts attached to the valve housing by hinges; the hinge points intersect the valve lumen resulting in a total of three openings. When pressurized blood hits the valve, the two halves of the circle fold away from the valve ring and allow blood to flow into the three openings before the valve flaps close again.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LWQ Heart-Valve, Mechanical
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P000037 002
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Outer Diameter: 23 Millimeter
CLOSE

Device Record Status

108b1d83-306c-4491-b867-fcf0978afe86
February 05, 2021
4
September 12, 2014
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE