DEVICE: Tenzing 7 Delivery Catheter (00853799007541)
Device Identifier (DI) Information
Tenzing 7 Delivery Catheter
Gen 1
In Commercial Distribution
ROUTE 92 MEDICAL
Gen 1
In Commercial Distribution
ROUTE 92 MEDICAL
Tenzing 7 Delivery Catheter
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
10691 | Vascular microcatheter |
A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.
|
Active | false |
58173 | Thrombectomy suction catheter |
A flexible or semi-flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native/stented blood vessels, native/synthetic bypass grafts, and/or haemodialysis access grafts, through suction (aspiration) in conjunction with a syringe or dedicated suction pump system (pump not included). It may additionally be intended for infusion of fluids and/or used as a guide-catheter to facilitate introduction of a thrombectomy wire-net (not included) to remove residual thrombus. Collection containers may be included with the catheter. This is a single-use device.
|
Active | false |
17846 | Vascular guide-catheter, single-use |
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system. It may be rigid or flexible, non-steerable or steerable, single or multiple lumen(s), and the distal section can have a variety of preformed shapes (e.g., straight, hockey stick). It is not intended solely for infusion, is not intended to access superselective small vessels, and does not include a transseptal needle. It may include a disposable percutaneous introduction set or shaft visualization electrodes. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQY | Catheter, Percutaneous |
NRY | Catheter, Thrombus Retriever |
QJP | Catheter, Percutaneous, Neurovasculature |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
946e13be-c0a9-4993-8fa0-55dbd4a8922e
May 24, 2024
1
May 16, 2024
May 24, 2024
1
May 16, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
650-350-9416
Customerservice@r92m.com
Customerservice@r92m.com