DEVICE: Tenzing 7 Delivery Catheter (00853799007541)

Device Identifier (DI) Information

Tenzing 7 Delivery Catheter
Gen 1
In Commercial Distribution

ROUTE 92 MEDICAL
00853799007541
GS1

1
067429673 *Terms of Use
Tenzing 7 Delivery Catheter
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
10691 Vascular microcatheter
A sterile, small-diameter, single-lumen, flexible tube designed for the controlled infusion of fluids (e.g., thrombolytics, diagnostic contrast media) into superselective small vessels (including intracranial, peripheral, or occluded coronary vasculature) for angiography/treatment, and typically also for the delivery of devices (e.g., embolization implants, guidewires) into tortuous vessels or across tight lesions. It may include an ultrasound transducer, a thermal sensor, and a hole for guidewire placement located at the distal tip. It is not a guide-catheter (i.e., is not intended to deliver other catheters or therapeutic leads directly through its lumen). This is a single-use device.
Active false
58173 Thrombectomy suction catheter
A flexible or semi-flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native/stented blood vessels, native/synthetic bypass grafts, and/or haemodialysis access grafts, through suction (aspiration) in conjunction with a syringe or dedicated suction pump system (pump not included). It may additionally be intended for infusion of fluids and/or used as a guide-catheter to facilitate introduction of a thrombectomy wire-net (not included) to remove residual thrombus. Collection containers may be included with the catheter. This is a single-use device.
Active false
17846 Vascular guide-catheter, single-use
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system. It may be rigid or flexible, non-steerable or steerable, single or multiple lumen(s), and the distal section can have a variety of preformed shapes (e.g., straight, hockey stick). It is not intended solely for infusion, is not intended to access superselective small vessels, and does not include a transseptal needle. It may include a disposable percutaneous introduction set or shaft visualization electrodes. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQY Catheter, Percutaneous
NRY Catheter, Thrombus Retriever
QJP Catheter, Percutaneous, Neurovasculature
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

946e13be-c0a9-4993-8fa0-55dbd4a8922e
May 24, 2024
1
May 16, 2024
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE