DEVICE: Constavac CBC III (00855168008647)

Device Identifier (DI) Information

Constavac CBC III
225-414-000W
In Commercial Distribution
225-414-000W
3T MEDICAL SYSTEMS, INC.
00855168008647
GS1

1
112462671 *Terms of Use
ConstaVac CBCIII Conservation Kit with 3.2 mm Round PVC Wound Drain
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47977 Whole-blood-recovery autotransfusion system, powered
An assembly of devices used to collect, filter, and reinfuse intraoperative and/or postoperative autologous blood shed during and/or after elective and non-elective surgery. It is a complete, closed-circuit system that typically includes a suction set or a catheter for blood access, a collection unit, an autotransfusion bag, safety clamps, non-return valves, various blood screening filters, and a transfusion set. The suction mechanism is typically actuated by a central vacuum system. A trocar may also be included. The device is typically used when there is a lack of donor blood or when compatible blood is not available. This is a single-use device.
Obsolete false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
CAC Apparatus, Autotransfusion
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K970714 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Humidity: between 10 and 75 Percent (%) Relative Humidity
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal
Storage Environment Temperature: between -20 and 40 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: 3.2 Millimeters
CLOSE

Device Record Status

3eaedbb6-c6d7-41ab-8ac0-189840860a64
July 16, 2019
2
March 01, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
00855168008630 6 00855168008647 In Commercial Distribution Pack
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
7345259580
sales@3tmedical.com
CLOSE