DEVICE: Professional Hand Evaluation Kit (00855170007119)

Device Identifier (DI) Information

Professional Hand Evaluation Kit
5030K1
In Commercial Distribution
5030K1
LAFAYETTE INSTRUMENT COMPANY, INC.
00855170007119
GS1

1
005080650 *Terms of Use
The Lafayette Grip or Pinch Dynamometers are hydraulic strength measuring instruments. They are designed for routine assessment of the grip and/or pinch strength of a patient or can also be used in the evaluation of hand trauma or disease. As the patient either grips or pinches the device, a column of hydraulic fluid activates a pressure gauge mounted on the top of the device. The gauge indicates the pinch or grip force in pounds (lbs) or kilogram force (kgf). A peak needle shows the maximum force applied during a single test. The peak needle is manually reset at the end of the test and peak values are recorded manually. The grip dynamometers also feature an adjustable handle that can accommodate five different grip positions. The Stainless Steel Short Finger Goniometer is used for easy range-of-motion measurements of metacarpal, phalangeal, and interphalangeal joints. There are linear inch and centimeter markings on both sides of the protractors, in opposite directions. The protractors measure 0-150° in 5° increments. Stainless steel. Latex free. Clearly marked numbers make measuring easy. Measures 5.75 inches long.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35021 Hand dynamometer/pinchmeter, mechanical
A non-powered, mechanical instrument designed to assess neuromuscular function by measuring the force or power exerted by the muscles of the hand/forearm to squeeze/pinch an object. It is used to assess a patient's grip and/or pinch strength in clinical or research settings, typically as part of a rehabilitation program for geriatric patients or those who have suffered a stroke. This device is commonly known as a Vigorimeter. It typically consists of various size squeeze bulbs and an analogue manometer to record the exerted effort. The patient will typically be asked to perform the test a few times so that the physician can obtain a mean value.
Active false
33651 Manual goniometer
A non-powered, manually-operated measuring device, graduated in degrees (e.g., from 0 to 360 degrees), designed to be used in a clinical setting to measure the range of motion of the limb of a patient by measuring the angle of movement achieved at the joint. It is typically used by rheumatologists, physiotherapists, orthopaedists and general practitioners to evaluate joint movement (e.g., ankle, finger, knee, shoulder or spine) before and after a medical/surgical intervention. It may be made of plastic or stainless steel and is available in various designs (e.g., protractor-like with pivoting arms, dial-like with twin rotating dials). This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HRW Dynamometer, Nonpowered
KQW Goniometer, Nonpowered
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 50 and 95 Degrees Fahrenheit
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

41facf4b-2b74-4b28-84f4-08b483d3868d
September 08, 2021
1
August 31, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
765-423-1505
bbrown@lafayetteinstrument.com
CLOSE