DEVICE: Espion (00855730007146)
Device Identifier (DI) Information
Espion
D310
In Commercial Distribution
DIAGNOSYS LLC
D310
In Commercial Distribution
DIAGNOSYS LLC
Profile System; with 27" Monitor and Mini OLED on extendable arm is a clinical and research visual electrophysiology system that functions by presenting a light stimulus to the eye, and then capturing, displaying, and storing the waveform of the electrical response from the retina (corneal electrode) or brain (occipital skin electrodes).
Configuration: D310-B-1-27F-N-X
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
11482 | Electroretinograph |
An ophthalmic device used to record the changes in electric potential on or near the surface of the cornea to a reference distal point on the body, following stimulation of the retina by light, i.e., flashes of white light. The electroretinograph (ERG) recorder is used with a primary electrode [typically gold (Au), platinum (Pt) or silver (Ag)] and a reference electrode located almost anywhere on the body, e.g., cheek or ear lobe, and an amplifier that boosts the bioelectrical potential. Some are compatible with a personal computer (PC) for waveform storage and analysis. It is used in the diagnosis of retinal degeneration, night blindness, and circulatory disturbances of the retina.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GWE | Stimulator, Photic, Evoked Response |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K863956 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Humidity: between 10 and 100 Percent (%) Relative Humidity |
Storage Environment Temperature: between -10 and 70 Degrees Celsius |
Handling Environment Atmospheric Pressure: between 50 and 106 KiloPascal |
Handling Environment Humidity: between 10 and 100 Percent (%) Relative Humidity |
Handling Environment Temperature: between -10 and 70 Degrees Celsius |
Storage Environment Atmospheric Pressure: between 50 and 106 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
b74c23fe-f5bd-4ec3-919c-ce252691ee35
December 17, 2018
1
November 14, 2018
December 17, 2018
1
November 14, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]