DEVICE: Decima Spine Instrument Kit (00857360007008)
Device Identifier (DI) Information
Decima Spine Instrument Kit
6072-00
In Commercial Distribution
6072-00
DECIMA SPINE, INC.
6072-00
In Commercial Distribution
6072-00
DECIMA SPINE, INC.
Kichner Wire
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
62746 | Orthopaedic trocar blade, single-use |
A sterile, rigid hand-held surgical instrument with a sharp (pyramidal or conical) point designed to be used during orthopaedic surgery for the manual puncture of a bodily entry point to: 1) gently part the surrounding soft tissue upon entry; 2) assist in the location and positioning of skeletal fractures; and/or 3) assist alignment of surgical instruments/implants. It is typically made of high-grade stainless steel, titanium (Ti), or synthetic material. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HXI | Passer, Wire, Orthopedic |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
64c6d219-6db1-4d86-b0b1-621ef6bae2c2
May 09, 2018
1
April 08, 2018
May 09, 2018
1
April 08, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1 (954) 243-6103
carlos@decimaspine.com
carlos@decimaspine.com