DEVICE: KneeAlign 2 (00858704006008)

Device Identifier (DI) Information

KneeAlign 2
133631
In Commercial Distribution
133631
Orthalign, Inc.
00858704006008
GS1

1
023266163 *Terms of Use
KneeAlign 2 Unit
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
45200 Orthopaedic stereotactic surgery system
An assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during orthopaedic surgery. The system may include computerized functions to store diagnostic images used for image-guided surgery.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OLO Orthopedic Stereotaxic Instrument
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 10 and 70 Percent (%) Relative Humidity
Handling Environment Temperature: between 15 and 25 Degrees Celsius
Special Storage Condition, Specify: Handle with care. Products should be stored in a clean, cool, dry area, away from chemical fumes.
Storage Environment Temperature: between -30 and 60 Degrees Celsius
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity
Storage Environment Atmospheric Pressure: between 60 and 101 KiloPascal
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

dfaf658a-f618-46d3-90f7-18080926324f
November 20, 2024
7
September 23, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
10858704006005 5 00858704006008 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
No
No CLOSE

Customer Contact

[?]
866-582-0879
CustomerService@orthalign.com