DEVICE: Caption AI (Caption Guidance + Caption Interpretation) (00860003586310)
Device Identifier (DI) Information
Caption AI (Caption Guidance + Caption Interpretation)
Adonis
In Commercial Distribution
511-00019
CAPTION HEALTH, INC.
Adonis
In Commercial Distribution
511-00019
CAPTION HEALTH, INC.
Caption AI (Caption Guidance + Caption Interpretation) on portable handheld ultrasound.
The Caption Guidance software is indicated for use in two-dimensional transthoracic echocardiography (2DTTE) for adult patients, specifically in the acquisition of the following standard views: Parasternal Long-Axis (PLAX), Parasternal Short-Axis at the Aortic Valve (PSAX-AV), Parasternal Short-Axis at the Mitral Valve (PSAX-MV), Parasternal Short-Axis at the Papillary Muscle (PSAX-PM), Apical 4-Chamber (AP4), Apical 5- Chamber (AP5), Apical 2-Chamber (AP2), Apical 3-Chamber (AP3), Subcostal 4-Chamber (SubC4), and Subcostal Inferior Vena Cava (SC-IVC).
The Caption Interpretation Automated Ejection Fraction software is used to process previously acquired transthoracic cardiac ultrasound images, to store images, and to manipulate and make measurements on images using an ultrasound device, personal computer, or a compatible DICOM-compliant PACS system in order to provide automated estimation of left ventricular ejection fraction. This measurement can be used to assist the clinician in a cardiac evaluation.
The Caption Interpretation Automated Ejection Fraction Software is indicated for use in adult patients.
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
40873 | Ultrasound imaging system application software |
An individual software program or group of programs, routines or algorithms that add specific image processing and/or analysis capabilities to a diagnostic ultrasound system configuration. A basic set of applications programs and routines are included with such computer-controlled imaging systems and they can be upgraded to correct programming errors or to add new system capabilities. Some applications software programs or program packages must be combined with specific hardware or firmware configurations in order to function as intended. Applications program packages are typically identified by a proprietary name and "version" or "upgrade" number.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
QJU | Image Acquisition And/Or Optimization Guided By Artificial Intelligence |
QIH | Automated Radiological Image Processing Software |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
8256d83d-6575-4021-ae97-99ee7dfbfdd4
May 29, 2025
3
March 15, 2022
May 29, 2025
3
March 15, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
(855) 506-4357
support@captionhealth.com
support@captionhealth.com