DEVICE: Axiostat Patch (00860008768681)

Device Identifier (DI) Information

Axiostat Patch
L88
In Commercial Distribution

Advamedica Inc.
00860008768681
GS1

1
118526617 *Terms of Use
Axiostat Patch is intended for local management of bleeding wounds and to provide a barrier to bacterial penetration of the dressing for patients and for the rapid control of moderate to severe bleeding. The dressing is indicated for the following wounds: lacerations, abrasions, surgical debridement sites, skin surface puncture sites, vascular procedure sites and sites involving percutaneous catheters, tubes and pins.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46922 Chitosan haemostatic agent, professional, non-bioabsorbable
A non-bioabsorbable device that includes chitosan (a polysaccharide derived from chitin, the structural element in the exoskeleton of crustaceans) as a principal component, intended to be applied exclusively by healthcare professionals in a clinical setting to traumatic wounds in emergency situations (e.g., road accidents, combat, emergency rescue) or during surgical intervention to produce a rapid haemostasis by forming a robust plug of gel which is removed after use. The chitosan may be intended to provide antibacterial activity, and is available in a variety of forms (e.g., fine particles in a pouch, coated on gauze). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
QSY Hemostatic Wound Dressing Without Thrombin Or Other Biologics
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K202830 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d97f6843-0d56-4fd4-9f45-c50cba0a0839
January 20, 2025
2
October 04, 2024
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE