DEVICE: TendoNova Ocelot (00860009899858)
Device Identifier (DI) Information
TendoNova Ocelot
DU1F80L-K
In Commercial Distribution
Tendonova Corporation
DU1F80L-K
In Commercial Distribution
Tendonova Corporation
TendoNova Disposable Unit 80mm Kit-Single
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44755 | Soft-tissue ultrasonic surgical system handpiece tip, single-use |
A sterile removable endpiece intended to be attached to an ultrasonic surgical system handpiece, and makes contact with a patient while oscillating (vibrating) at high frequency in order to fragment soft-tissue cells for cutting and/or coagulating tissue during surgery. The device comes in a variety of forms (e.g., blade, cylinder, pincers) and sizes, and is typically made of metal; it is not intended to be held directly (i.e., does not include a holder). This device is utilized in a variety of surgical disciplines (e.g., neurosurgery, general surgery, surgical oncology, gynaecology, and urology). This is a single-use device.
|
Active | false |
47788 | Spiral blade |
An implantable, rod-like, cannulated device with spiralled flutes at the distal end and a smooth cylindrical portion at the proximal end that is used in combination with a bone fixation plate or an intramedullary nail to support bone fragments after fractures, particularly in the proximal femur or proximal humerus (the bone heads). It is made of metal that cannot be chemically degraded (e.g., surgical steel, titanium alloy). It is intended to decrease the amount of removed bone required for device insertion, and provides a support surface in the zone requiring support (bone head) and resistance to bending in the zone most subject to torque.
|
Active | true |
15321 | Skin topical coupling gel |
A medium designed to be applied to a patient's unbroken skin surface (excludes the eye surface) to provide a coupling between an analytical or therapeutic device (e.g., ultrasound transducer, optical glucose monitoring system, transcutaneous electrical stimulator) and the patient, allowing for the emission and reception of energy/signals (e.g., electrical current, light) that pass through the skin during an examination or treatment. It is in the form of a fluid-like gel that may also assist in moving the parent device smoothly over the skin. It may be used by a healthcare professional in a clinical setting and layperson in the home. After application, this device cannot be reused.
|
Active | false |
44990 | Skin-cover adhesive strip, non-antimicrobial |
A small, narrow, flexible band (of fabric, plastic, paper, or other material) coated on one side with a pressure-sensitive adhesive and possibly with an absorbent pad, typically intended to cover a superficial wound or fix a dressing to skin. It may be hypoallergenic and/or waterproof, however it does not include antimicrobial agents/properties. Commonly referred to as a sticking plaster, it is intended for use in the home or a clinical setting. This is a single-use device.
|
Active | false |
47783 | Patient surgical drape, single-use |
A noninvasive sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to function as a barrier to cross contamination (e.g., isolate a site of surgical incision, protect non-operative anatomy). It is not designed with specific heat-reflective or laser resistant materials. It is available in a variety of designs (e.g., flat sheet with or without an access hole, leg tube or an adhesive film sheet otherwise known as an incise drape). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LFL | Instrument, ultrasonic surgical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K212049 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 80 Millimeter |
Device Record Status
cf090c65-ac12-4603-8101-109669eeeb6f
December 13, 2023
1
December 05, 2023
December 13, 2023
1
December 05, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined