DEVICE: TAS Medical, Inc. Tissue Approximation System (00860011435907)
Device Identifier (DI) Information
TAS Medical, Inc. Tissue Approximation System
T-4000
In Commercial Distribution
T-4000
TAS Medical, Inc.
T-4000
In Commercial Distribution
T-4000
TAS Medical, Inc.
The Tissue Approximation System (TAS) consists of a polyamide (nylon) “zip-tie” attached to a braided polyethylene terephthalate (PET, or Dacron) leader to aid insertion. A one-way clasp allows for fixation of the tissue approximation without the need to tie surgical knots.
When packaged for commercial distribution, four zip-ties with integrated suture leaders are accompanied by hand-held instruments that can be optionally used for insertion. The kit will be provided sterile within a polyethylene/Tyvek pouch.
Device Characteristics
MR Safe | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
38000 | Nylon suture, non-bioabsorbable, monofilament |
A single-strand (monofilament), synthetic, non-bioabsorbable thread made of nylon (a polyamide polymer) intended to join (i.e., approximate) the edges of a soft-tissue wound or incision by stitching or to ligate soft tissues; it may include an attached disposable device(s) [e.g., needle, passer] intended to facilitate suture application. The thread provides temporary wound support until the wound sufficiently heals. It is not a barbed suture and does not include antimicrobial agents/materials. This is a single-use device.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GAR | Suture, Nonabsorbable, Synthetic, Polyamide |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K220980 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 37 Centimeter |
Width: 2.7 Millimeter |
Height: 1.4 Micrometer |
Device Record Status
97beb2e0-a83c-47d1-8fb2-949445792fc8
January 16, 2024
1
January 08, 2024
January 16, 2024
1
January 08, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined