DEVICE: Cruzar Medsystems Inc. (00860554000327)

Device Identifier (DI) Information

Cruzar Medsystems Inc.
CM-3700
Not in Commercial Distribution

CRUZAR MEDSYSTEMS INC
00860554000327
GS1
October 16, 2019
1
080338871 *Terms of Use
The Houdini Catheter is a single use, dual-lumen intravascular catheter intended for percutaneous use. The Houdini Catheter is intended to be used in conjunction with a steerable guidewire to access discrete regions of the peripheral vasculature and for guidewire exchange.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
17846 Vascular guide-catheter, single-use
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system. It may be rigid or flexible, non-steerable or steerable, single or multiple lumen(s), and the distal section can have a variety of preformed shapes (e.g., straight, hockey stick). It is not intended solely for infusion, is not intended to access superselective small vessels, and does not include a transseptal needle. It may include a disposable percutaneous introduction set or shaft visualization electrodes. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQY Catheter, Percutaneous
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Pressure: 176 Pound per Square Inch
Lumen/Inner Diameter: .035 Inch
Length: 100 Centimeter
Device Size Text, specify: 7mm x 2cm Balloon
Catheter Gauge: 6 French
CLOSE

Device Record Status

7d15aa52-802d-49f8-879b-b054c9386d3a
December 22, 2021
8
August 26, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined