DEVICE: Centripid PC (00861122000305)
Device Identifier (DI) Information
Centripid PC
CELL-80180-A
In Commercial Distribution
CELL-80180-A
CELLMEDIX HOLDINGS, LLC
CELL-80180-A
In Commercial Distribution
CELL-80180-A
CELLMEDIX HOLDINGS, LLC
The Centrepid PC design concept is predicated on providing an easy to use device for platelet rich plasma (PRP) that demonstrates high platelet yield in a highly reproducible manner. This is accomplished by inclusion of design elements that provide appropriate directional, and selectable, cell layer aspiration within the horizontally dispersed “buffy coat” in the centrifuge tube design. The design resembles the shape, and general construction, of a standard 50ml centrifuge tube, but differs from such standard products by inclusion of proprietary structural components. The similarities in design allow such devices to be centrifuged in any tabletop centrifuge that accepts a 50ml tube and is, additionally, capable of 1900 RCF at 3500 RPM, 4X50ml capacity and 30-minute timer.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46923 | Haematological concentrate system preparation kit, platelet concentration |
A collection of devices designed to prepare platelet-rich plasma (PRP) or platelet-rich fibrin matrix (PRFM) from an autologous blood specimen for application to soft-tissue wounds and injured bone to accelerate healing and/or achieve haemostasis. It includes single- or double- (concentric) barrel syringe(s) with connecting tubes and caps. Blood is collected by venous puncture and processed in a centrifuge, increasing the concentration of platelets within the plasma or fibrin matrix; this may be done at the point-of-care. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
ORG | Platelet And Plasma Separator For Bone Graft Handling |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
BK130079 | 0 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
19cd8cdb-6c0d-46ef-a1e3-e3b7f4cdf0f4
July 23, 2020
5
January 09, 2017
July 23, 2020
5
January 09, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10861122000302 | 10 | 00861122000305 | 2017-01-04 | Not in Commercial Distribution | Shipper Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-800-392-6310
info@cellmedix.com
info@cellmedix.com