DEVICE: Heron IOS (00864206000406)

Device Identifier (DI) Information

Heron IOS
IOS-FP-71-001
In Commercial Distribution

3D IMAGING AND SIMULATION CORP. AMERICAS
00864206000406
GS1

1
117033482 *Terms of Use
Heron IOS system is an optical impression system used to record the topographical characteristics of teeth, dental impressions, or stone models for use in the computer aided design and manufacturing of dental restorative prosthetic devices. Heron IOS system consists of a handheld scanner with base, tips (reusable upon autoclave), cables and software.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
38597 Dental milling system, CAD/CAM, chairside
An assembly of devices designed for automated computer-aided design (CAD) and computer-aided manufacturing (CAM) of custom-made (prescribed for one patient) dental restorations produced chairside during dental or orthodontic treatment. It typically includes, or is used in conjunction with, three-dimensional (3-D) image acquisition and viewing capabilities that provide values (measurements) for the production phase; software for record collection, treatment planning, simulation and device production; and robotic capabilities for the production of the actual devices to be fitted to the patient.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
NOF System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -20 and 60 Degrees Celsius
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Storage Environment Humidity: between 10 and 80 Percent (%) Relative Humidity
Handling Environment Humidity: between 10 and 80 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

e7fb3fd6-61fb-4bb5-ba74-b9cebbfba935
April 04, 2023
4
September 13, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+1 800 570 0363
info@3disc.com
CLOSE