DEVICE: X-ray Imaging System (XIS) (00866854000401)

Device Identifier (DI) Information

X-ray Imaging System (XIS)
v.1.x
In Commercial Distribution
n/a
EhmetDx LLC
00866854000401
GS1

1
116979727 *Terms of Use
The X-ray Imaging System controls the x-ray generation, image processing and patient registration of the McLaren Proton Treatment System. The software product described by this document is considered a sub-system of the MPTS. The software product integrates with the following components of the MPTS system: • X-ray generator & tube assembly • Amorphous silicon flat-panel detector • Electro-mechanical controls of the imaging c-ring to enable system positioning and rotation around the patient The software will permit a radiation technician to set the desired energy levels and field of view. Once set the software can acquire orthogonal or CBCT x-ray images of the region of interest. When images are acquired the software will process them to create viewable images for patient location registration. The patient location registration workflow will locate the treatment isocenter, defined in the patient anatomy, relative to the desired position in the treatment room through which the beam passes. The location of the treatment isocenter is established during treatment planning with 3D planning images (CT simulation images). The patient’s position will be adjusted, if needed, based on a comparison of the current patient location, the defined treatment plan, and previously acquired Digitally Reconstructed Radiographs or CTs. There are two defined methods of registration, 1. Digitally Reconstructed Radiographs (DRRs) from 3D planning images are compared to the 2D images taken during patient setup in order to compare the patient anatomy with the expected location and orientation given by the DRRs. The registration tool is implemented to display both the downloaded DRRs, provided by the treatment planning system, and the display of the new 2D images, acquired by x-ray imaging system. 2. 3D planned volume images are compared to the CBCT volumetric (CTs) images taken during patient setup in order to compare the patient anatomy with the expected location and orientation. The regis
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
40867 CT system application software
An application software program intended to add specific image processing and/or analysis capabilities to an x-ray computed tomography (CT) imaging system; it is not dedicated to radiotherapy treatment planning. A basic set of applications programs and routines are included with such computer-controlled imaging systems and they can be upgraded to correct programming errors or to add new system capabilities. Some applications software routines or groups of routines must be combined with specific hardware or firmware accessories or configurations in order to function as intended. Applications program packages are typically identified by a proprietary name and version or upgrade number.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LHN System, Radiation Therapy, Charged-Particle, Medical
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K181498 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

c23570d6-5694-4d63-9680-1bd12b2fb0a7
March 31, 2025
1
March 21, 2025
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
No
No
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE