DEVICE: Mikro-Tip Catheter Pulse Transducer (00868924000236)

Device Identifier (DI) Information

Mikro-Tip Catheter Pulse Transducer
SPT-301
In Commercial Distribution
808-1019
MILLAR INC.
00868924000236
GS1

1
058269648 *Terms of Use
Mikro-Tip catheters consist of an ultra-miniature pressure sensor(s) at the distal end of a catheter with an electrical connector(s) at the proximal end. The pressure sensor produces an electrical output signal, which varies in direct proportion to the magnitude of sensed pressure or sound. Mikro-Tip catheters are intended for multiple uses.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
15071 Catheter-tip transducer, pressure
A device intended to be incorporated into the distal end of a catheter (not included) to measure pressure. It typically consists of a pressure sensor (e.g., a flexible membrane or diaphragm) and a means to convert the detected pressure into electronic signals or possibly ultrasonic signals which are transmitted via a cable or wireless to an external parent device (e.g., a manometer) that processes the signals and displays the results. It is used for invasive measurement of pressure in places such as the central and/or peripheral vasculature, cranium, uterus (typically during labour), pleura, and also in the urinary bladder/urethra (e.g., during urodynamic tests). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DXO Transducer, Pressure, Catheter Tip
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K895721 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

55817e2f-4286-49a2-8ce2-c320f9ff4a43
July 06, 2018
4
October 21, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
832-667-7000
sales@millar.com
CLOSE