DEVICE: microTargeting™ Insertion Tube Set (00873263001301)

Device Identifier (DI) Information

microTargeting™ Insertion Tube Set
FC1011-00130
Not in Commercial Distribution
FC1011
FHC, INC.
00873263001301
GS1
January 10, 2023
1
108179458 *Terms of Use
microTargeting Single Electrode Insertion Tube Set Contains: 66-IT-01 (One IT(BP2), One PT(BP2), One Spacer Cleaning Tool, One Electrode Carrier, One Shielded Electrode Carrier) depth when used with frame and Star or mT Drive is 40mm above target Individual Specifications: IT(BP2): Length=183mm, OD=1.83mm, ID=1.60mm PT(BP2): Length=181mm, OD=1.47mm, ID=0.99mm
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61964 Intracerebral cannula, implantable
A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade.
Active true
46863 Neurosurgical micro targeting drive
A calibrated guide mechanism used by a surgeon to manually operate a Z-axis positioner which allows extremely accurate placement of a single or multiple microelectrodes, stimulation electrodes, probes, instruments, or implantable devices, along a chosen track during neurosurgery on the brain. It is intended to be used with a neurosurgical stereotactic system. It typically consists of a metal, graduated frame along which an instrument holder traverses (e.g., approximately 50 mm) by adjustment of a graduated knob that revolves a fine pitched lead screw (e.g., one revolution of the knob will advance the drive by 1 mm). Some types can have an electrical motor attached for motorized drive.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HAW Neurological stereotaxic Instrument
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K011775 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Ethylene Oxide
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
Storage Environment Temperature: between 0 and 40 Degrees Celsius
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 40 Millimeter
CLOSE

Device Record Status

539e3971-75cd-4933-a77f-fb3c0afec20d
January 10, 2023
5
August 22, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)326-2905
fhcinc@fh-co.com