DEVICE: microTargeting™ Insertion Tube Set (00873263001523)
Device Identifier (DI) Information
microTargeting™ Insertion Tube Set
FC1011-00152
Not in Commercial Distribution
FC1011
FHC, INC.
FC1011-00152
Not in Commercial Distribution
FC1011
FHC, INC.
microTargeting Single Electrode Insertion Tube Set
Contains:
66-IT-01 (One IT(BP2), One PT(BP2), One Spacer Cleaning Tool, One Electrode Carrier, One Shielded Electrode Carrier) depth when used with frame and Star or mT Drive is 40mm above target
Individual Specifications:
IT(BP2): Length=183mm, OD=1.83mm, ID=1.60mm
PT(BP2): Length=181mm, OD=1.47mm, ID=0.99mm
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61964 | Intracerebral cannula, implantable |
A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade.
|
Active | true |
46863 | Neurosurgical micro targeting drive |
A calibrated guide mechanism used by a surgeon to manually operate a Z-axis positioner which allows extremely accurate placement of a single or multiple microelectrodes, stimulation electrodes, probes, instruments, or implantable devices, along a chosen track during neurosurgery on the brain. It is intended to be used with a neurosurgical stereotactic system. It typically consists of a metal, graduated frame along which an instrument holder traverses (e.g., approximately 50 mm) by adjustment of a graduated knob that revolves a fine pitched lead screw (e.g., one revolution of the knob will advance the drive by 1 mm). Some types can have an electrical motor attached for motorized drive.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HAW | Neurological stereotaxic Instrument |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K011775 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 0 and 40 Degrees Celsius |
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 40 Millimeter |
Device Record Status
1dbd6e18-f235-40dd-b23a-6cd9cbc4cde1
January 10, 2023
5
September 09, 2017
January 10, 2023
5
September 09, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)326-2905
fhcinc@fh-co.com
fhcinc@fh-co.com