DEVICE: microTargeting™ Protective Tube (00873263006672)
Device Identifier (DI) Information
microTargeting™ Protective Tube
66-PT(FP3)-00667
In Commercial Distribution
66-PT(FP3)
FHC, INC.
66-PT(FP3)-00667
In Commercial Distribution
66-PT(FP3)
FHC, INC.
microTargeting™ Tandem Protective Tube, nonsterile
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61854 | Intracerebral cannula, nonimplantable, reusable |
A nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, leads and/or probes can be passed to perform a variety of diagnostic, treatment, or surgical procedures. It is usually made of metal (e.g., stainless steel) and may include a stylet/trocar blade. This is a reusable device intended to be sterilized prior to use.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HAW | Neurological stereotaxic Instrument |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K011775 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 0 and 40 Degrees Celsius |
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
Outer Diameter: 1.24 Millimeter |
Lumen/Inner Diameter: 0.96 Millimeter |
Length: 209 Millimeter |
Device Record Status
7b788342-9666-4f09-8add-0acc11d247af
July 06, 2018
2
May 18, 2018
July 06, 2018
2
May 18, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)326-2905
fhcinc@fh-co.com
fhcinc@fh-co.com