DEVICE: ECHO BI-METRIC HIP SYSTEM (00880304463240)

Device Identifier (DI) Information

ECHO BI-METRIC HIP SYSTEM
192108
In Commercial Distribution
192108
Biomet Orthopedics, LLC
00880304463240
GS1

1
129278169 *Terms of Use
No description.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
38155 Press-fit femoral stem prosthesis
A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is contoured to enable fixation by pressing the distal end into the cortex of the remaining natural femur to achieve a mechanical interlock without the use of bone cement. The device is made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel].
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MAY Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous cemented, osteophilic finish
LWJ Prosthesis, hip, semi-constrained, metal/polymer, uncemented
KWL Prosthesis, hip, hemi-, femoral, metal
LPH PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
KWY Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented
KWZ Prosthesis, hip, constrained, cemented or uncemented, metal/polymer
MEH Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate
JDI Prosthesis, hip, semi-constrained, metal/polymer, cemented
LZO Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K070274 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: 8 SIZE 120 MM TYPE I TAPER
CLOSE

Device Record Status

80922aba-024e-4b78-a1cb-b5856b16a679
May 30, 2025
4
October 24, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)348-9500
customerservice@zimmerbiomet.com