Device Identifier (DI) Information
Biomet®
010001039
In Commercial Distribution
010001039
Biomet Orthopedics, LLC
010001039
In Commercial Distribution
010001039
Biomet Orthopedics, LLC
No description.
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 33175 | Metallic femoral head prosthesis |
An implantable artificial substitute for a diseased or injured femoral head that has an outer surface made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel]. It is designed to be attached to the trunnion of a prosthetic femoral stem/shaft or a head/stem adaptor, and to articulate with an acetabulum prosthesis as part of a total hip arthroplasty (THA), or articulate with the natural acetabulum directly or via a bipolar component as part of a partial hip arthroplasty (hemiarthroplasty). The device ranges in form from partially to fully spherical (ball-shaped) and is available in various sizes.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| OQH | Hip, semi-constrained, cemented, metal/polymer + additive, cemented |
| PBI | prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive |
| OQI | Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented |
| LPH | PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED |
| LZO | Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented |
| OQG | Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented |
| JDI | Prosthesis, hip, semi-constrained, metal/polymer, cemented |
| LWZ | TISSUE GRAFT OF LESS THAN 6MM |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K121874 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: 44 mm Head Size +9 Neck Length |
Device Record Status
16fd38e1-ad23-4fd5-b7a0-bcd1df2d2cf7
May 30, 2025
7
October 24, 2015
May 30, 2025
7
October 24, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)348-9500
customerservice@zimmerbiomet.com
customerservice@zimmerbiomet.com