DEVICE: Vanguard Complete Knee System (00880304552425)
Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to
GUDIDSupport@fda.hhs.gov.
Device Identifier (DI) Information
Vanguard Complete Knee System
195894
In Commercial Distribution
195894
Biomet Orthopedics, LLC
195894
In Commercial Distribution
195894
Biomet Orthopedics, LLC
No description.
Device Characteristics
| MR Conditional | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 33666 | Uncoated knee tibia/insert prosthesis |
A sterile implantable device designed to replace the tibial condyles (tibial component) during primary bicondylar replacement of the knee joint or to replace a dysfunctional knee prosthesis (revision). It is made of metal [e.g., cobalt-chrome (Co-Cr)] and is not coated with a material intended to improve fixation and stability by promoting bone ingrowth; it includes a polyethylene (PE) insert/platform for femoral articulation. Device implantation is intended to be performed with bone cement.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| OIY | Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer + additive/metal/polymer + additive |
| MBV | Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer |
| MBH | PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER |
| JWH | PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: 12MM THICKNESS 79/83 TRAY |
Device Record Status
89038005-bbdb-4b32-a835-c9cb37cfc32f
May 30, 2025
5
October 24, 2015
May 30, 2025
5
October 24, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)348-9500
customerservice@zimmerbiomet.com
customerservice@zimmerbiomet.com