DEVICE: LIFEPAK 15 monitor/defibrillator (00883873870228)
Device Identifier (DI) Information
LIFEPAK 15 monitor/defibrillator
41577
In Commercial Distribution
41577-000289
PHYSIO-CONTROL, INC.
41577
In Commercial Distribution
41577-000289
PHYSIO-CONTROL, INC.
LP15 ACCRY SHIPKIT,AHA,L
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
35562 | Electrocardiographic lead set, reusable |
A collection of noninvasive devices intended to conduct electrical signals from a patient's heart, via an electrode attached to the surface of the chest/limbs, to an electrocardiograph (ECG) machine or a patient monitoring system. It is designed as an insulated wire(s), which may additionally include a detachable or permanently attached electrode and/or cable with connector. Some types may be designed as a pre-configured array (e.g., EEG belt) to assist electrode placement. This is a reusable device.
|
Active | false |
37340 | General-purpose patient temperature probe, reusable |
A temperature sensing device intended to be placed into a body orifice or on the body surface and used in conjunction with a separate parent device with a display (e.g., electronic patient thermometer, infant warmer) to enable measurement/monitoring of a patient’s temperature; its use is not dedicated to a specific type of procedure. It is typically constructed of flexible materials (e.g., plastic or rubber) with a metal conducting core; the distal end of different device types will be designed for a particular application site. This is a reusable device.
|
Active | false |
34978 | Blood pressure cuff, reusable |
A band-like device that has an inflatable bladder in an inelastic sleeve with one or two connecting tubes with connector (typically locking connectors) that can be connected to a mechanism for inflating and deflating the bladder and/or a sphygmomanometer or a patient monitoring device/system that is used to determine a patient's blood pressure. It is wrapped around the upper arm or the leg (thigh) of the patient. This is a reusable device which may be intended for single-patient or multi-patient reuse.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
No Product Codes |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
501f685c-cd48-4195-acce-33400c3b2ab5
June 06, 2024
4
May 23, 2019
June 06, 2024
4
May 23, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)442-1142
rs.seacustomersupport@stryker.com
rs.seacustomersupport@stryker.com