DEVICE: Temperature Module (00884838021082)
Device Identifier (DI) Information
Temperature Module
Temperature Parameter Module
In Commercial Distribution
862291
Philips Medizin Systeme Böblingen GmbH
Temperature Parameter Module
In Commercial Distribution
862291
Philips Medizin Systeme Böblingen GmbH
Temperature Parameter Module for use with IntelliVue Patient Monitors MP40-MP90 and MX500-MX800. The Temperature Module provides continuous body temperature readings at a variety of sites including skin, rectal, nasal, esophageal, arterial, and venous.
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
36562 | Patient monitoring system module, temperature |
A small unit dedicated to the measurement and display of the patient's body temperature at one or more body sites. Signals are typically obtained through connected temperature probes, e.g., skin, rectal. It is designed to operate as part of a patient monitoring system enhancing the function of this system (the parent device). The module automatically plugs into the parent device when the user places it into a standardized slot in the parent device or a connected module rack. The parent device operates as a mainframe computer displaying the body temperature information measured and provided by this module.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
FLL | Thermometer, electronic, clinical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 60 Degrees Celsius |
Storage Environment Temperature: between -4 and 140 Degrees Fahrenheit |
Storage Environment Atmospheric Pressure: between 57 and 106 KiloPascal |
Storage Environment Humidity: between 15 and 90 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
e8699f8e-d618-4345-8b6f-37cc287d15b2
May 05, 2023
7
November 22, 2016
May 05, 2023
7
November 22, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(999)999-9999