DEVICE: PHILIPS HeartStart FRx (00884838080768)
Device Identifier (DI) Information
PHILIPS HeartStart FRx
Heartstart FRx
In Commercial Distribution
861304
PHILIPS ELECTRONICS NORTH AMERICA CORPORATION
Heartstart FRx
In Commercial Distribution
861304
PHILIPS ELECTRONICS NORTH AMERICA CORPORATION
HeartStart FRx Defibrillator
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47910 | Non-rechargeable public semi-automated external defibrillator |
A portable electronic device designed to automatically detect cardiac arrhythmias (ventricular fibrillation/pulseless ventricular tachycardia) in a sudden cardiac arrest (SCA) patient, after which it audibly/visually instructs an operator to enable it to activate defibrillation of the heart through application of electrical shocks to the chest surface. It is placed in conspicuous public locations and is intended to be operated by a layperson. It consists of two skin-adhesive, cartridge-type, disposable electrodes containing non-rechargeable batteries that provide the shock energy, and an electrode-regulating external pulse generator (EPG), which may include a CPR feedback.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MKJ | Automated external defibrillators (non-wearable) |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 60 Degrees Celsius |
Storage Environment Temperature: between -5 and 140 Degrees Fahrenheit |
Storage Environment Atmospheric Pressure: between 5 and 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
96c21ea6-1319-43a9-b448-e897400eb033
August 13, 2024
6
June 10, 2016
August 13, 2024
6
June 10, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(999)999-9999
xx@xx.xx
xx@xx.xx