DEVICE: Hemo-Flow® (00884908017182)
Device Identifier (DI) Information
Hemo-Flow®
HFS 28
Not in Commercial Distribution
Medical Components, Inc.
HFS 28
Not in Commercial Distribution
Medical Components, Inc.
14.5F X 28CM Hemo-Flow® DOUBLE LUMEN CATHETER SET (CUFF 23CM FROM TIP)
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| Yes | |
| Yes | |
| Yes | |
| No | |
| Yes | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 37278 | Double-lumen haemodialysis catheter, implantable |
An implantable, flexible, double-lumen tube intended to be used for chronic or long-term (> 30 days) vascular access, primarily during haemodialysis, to conduct blood from a patient and returning it after extracorporeal circulation; it may also be used during haemoperfusion and/or apheresis. It is intended for coaxial flow of blood, may be radiopaque, coated with heparin to prevent thrombus formation, and/or include a silver-coated sleeve to retard bacterial growth; devices dedicated to catheter introduction/function (e.g., introducer needle) may be included.
|
Active | true |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| MSD | Catheter, hemodialysis, implanted |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
0b166e60-9fef-407c-839a-ea17e90e70e9
February 05, 2021
5
October 27, 2015
February 05, 2021
5
October 27, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| 50884908017187 | 5 | 00884908017182 | 2021-01-29 | Not in Commercial Distribution | box |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(215)256-4201
clinical@medcompnet.com
clinical@medcompnet.com