DEVICE: G7® (00887868461118)

Device Identifier (DI) Information

G7®
010002641
In Commercial Distribution
010002641
Biomet Orthopedics, LLC
00887868461118
GS1

1
129278169 *Terms of Use
No description.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58480 Acetabulum prosthesis trial, prefabricated, reusable
A copy of a final acetabular prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct size and position of the final acetabular prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, is typically made of metal or polymer material and may be designed in the form of cages, shells, augments, or inserts. This is a reusable device intended to be sterilized prior to use.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OQG Hip Prosthesis, semi-constrained, cemented, metal/polymer, + additive, porous, uncemented
PBI prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive
LWZ TISSUE GRAFT OF LESS THAN 6MM
KWZ Prosthesis, hip, constrained, cemented or uncemented, metal/polymer
OQI Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented
LZO Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented
JDI Prosthesis, hip, semi-constrained, metal/polymer, cemented
OQH Hip, semi-constrained, cemented, metal/polymer + additive, cemented
LPH PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K121874 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: 40 mm J
CLOSE

Device Record Status

5d47de70-b900-4c39-93d1-3100761acf77
May 28, 2021
1
May 20, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(800)348-9500
customerservice@zimmerbiomet.com
CLOSE