DEVICE: Arcos® Modular Revision System (00887868466618)
Device Identifier (DI) Information
Arcos® Modular Revision System
110018389
In Commercial Distribution
110018389
Biomet Orthopedics, LLC
110018389
In Commercial Distribution
110018389
Biomet Orthopedics, LLC
No description.
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| No | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 45114 | Bone-resection orthopaedic reamer, reusable |
An orthopaedic surgical instrument intended to resect bone (cut out part of the bone), and in some cases hypertrophic tissue [e.g., ligamentum flavum], to: 1) accept a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna); and/or 2) relieve pressure at or facilitate access to a joint. Commonly called a mill or a reamer, it is typically designed as a stainless steel cylindrical body with an end/circumferential cutting edge and is attached to a shaft for manual or powered rotation. This is a reusable device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| LPH | PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED |
| JDI | Prosthesis, hip, semi-constrained, metal/polymer, cemented |
| KWZ | Prosthesis, hip, constrained, cemented or uncemented, metal/polymer |
| MAY | Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous cemented, osteophilic finish |
| LZO | Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented |
| KWY | Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented |
| MEH | Prosthesis, hip, semi-constrained, uncemented, metal / polymer, non-porous, calcium phosphate |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K090757 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Device Size Text, specify: Size B |
Device Record Status
b47e25d9-7c92-4db2-bfa0-cef8534d6dc0
May 30, 2025
4
April 23, 2022
May 30, 2025
4
April 23, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)348-9500
customerservice@zimmerbiomet.com
customerservice@zimmerbiomet.com