DEVICE: Arthrex® (00888867107519)

Device Identifier (DI) Information

Arthrex®
AR-513-BG18
In Commercial Distribution
AR-513-BG18
ARTHREX, INC.
00888867107519
GS1

1
131747628 *Terms of Use
IBAL TKA,BEARING IMP,PS,SZ 6,18MM
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47807 Surgical implant/trial-implant/sizer holder, reusable
A hand-held manual surgical instrument designed to connect to and hold an implant (e.g., bone screw, bone graft), trial implant, or implantable device sizer/template (e.g., glenoid defect sizer, hearing implant template) to facilitate guidance, gauging/sizing, and/or monitoring of the held device during orthopaedic or ear/nose/throat (ENT) surgery. The instrument is typically made of metal or synthetic polymer materials and is typically constructed in the form of a long shaft with a handle at the proximal end and a device holding/fixation mechanism at the distal end. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HSX PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER
MBH PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER
KRR PROSTHESIS, KNEE, PATELLO/FEMORAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d237c6f2-daec-4d3f-85f5-133dad8f5939
January 08, 2024
8
February 15, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M150AR513BG181
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)934-4404