DEVICE: SIDUS® STEM-FREE SHOULDER (00889024273009)
Device Identifier (DI) Information
SIDUS® STEM-FREE SHOULDER
01.04555.640
In Commercial Distribution
01.04555.640
Zimmer GmbH
01.04555.640
In Commercial Distribution
01.04555.640
Zimmer GmbH
No description.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45109 | Orthopaedic reamer guide |
An orthopaedic surgical device that functions as a guide for an orthopaedic reamer. The guide, commonly called a spigot, is inserted into a predetermined site where bone is to be resected for the acceptance of a prosthetic implant, typically at or within a joint (e.g., the condyle head of the knee, the olecranon of the ulna) or for the reaming of the intramedullary canal for acceptance of an intramedullary nail. The device allows the controlled cutting action of the reamer which is steered down its length. It is typically made of a high-grade stainless steel alloy; it comes in varying sizes. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KWS | PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED |
HSD | PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED |
PHX | shoulder prosthesis, reverse configuration |
PKC | Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained |
KWT | PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 100 Millimeter |
Outer Diameter: 2 Millimeter |
Device Record Status
d8cbddf9-a46f-4fa8-93cd-4648dc900c3b
November 28, 2019
4
September 24, 2016
November 28, 2019
4
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
00889024297838
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)348-2759
zimmer.consumerrelations@zimmerbiomet.com
zimmer.consumerrelations@zimmerbiomet.com