DEVICE: Easy Talk Blood Glucose Monitoring System (00891237001478)

Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to GUDIDSupport@fda.hhs.gov.

Device Identifier (DI) Information

Easy Talk Blood Glucose Monitoring System
6277
In Commercial Distribution
1478
HOME AIDE DIAGNOSTICS, INC.
00891237001478
GS1

1
783518983 *Terms of Use
Blood Glucose Testing Monitor to be used with Easy Talk or Easy Plus II test strips Test: Glucose Sample: Whole Blood Principle of the test method: Amperometric, glucose oxidase Test sites: Fingertip, forearm Measurement time: 6 seconds Code required: No code device Measurement Range: 20~600 mg/dL (1.1~33.3mmol/L ). Batteries: 2 x AAA 1.5 V Alkaline 24A LR03
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
Yes
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
62537 Glucose monitoring system IVD, home-use
A collection of devices including a portable, battery-powered, semi-automated or automated instrument (self-testing meter), reagents, test strips and/or other associated materials and accessories (e.g., control solutions, lancets) intended to be used for the quantitative measurement of glucose in a whole blood clinical specimen; it is designed to be used for self-testing by a layperson in the home, and some types may in addition be used at the point-of-care. Measured glucose values are used to manage blood glucose levels, primarily by persons with diabetes mellitus.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
NBW System, Test, Blood Glucose, Over The Counter
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d79cbfaa-25b5-422d-8b17-c71a622453d1
October 03, 2019
4
May 01, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
10891237001475 5 00891237001478 In Commercial Distribution Inner Case
20891237001472 10 10891237001475 In Commercial Distribution Outer Case
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
18009150116
info@homeaide.us
CLOSE