DEVICE: Chromascopics Control Level 1&2 Set 4x120mL (International) (00896863002035)
Device Identifier (DI) Information
Chromascopics Control Level 1&2 Set 4x120mL (International)
1540-01
In Commercial Distribution
1540-01
QUANTIMETRIX CORPORATION
1540-01
In Commercial Distribution
1540-01
QUANTIMETRIX CORPORATION
The Chromascopics Urinalysis Control with Microscopics is intended as an assayed quality control for the Siemens Clinitek Novus Automated Urine Chemistry Analyzer and Atellica 800 and 1500 systems. It is also compatible with Siemens urinalysis dipsticks, confirmatory tests, and qualitative methods. It may also be used as a means of validating the processing and centrifugation of patient urine samples prior to the microscopic evaluation of urine sediment. It is supplied as a liquid, ready-to-use control in two levels, configured with 2x120mL of each level per box. It does not required reconstitution or dilution. They are prepared from human urine to which stabilized human red and white blood cells, calcium oxalate crystals, non-pathogenic bacteria, and other compounds have been added to produce desired reactions when tested by the methods indicated in the product insert. Preservatives have been added to inhibit microbial growth.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
42065 | Urine sediment IVD, control |
A material which is used to verify the performance of an assay intended to be used for the qualitative and/or semi-quantitative screening of urine sediment.
|
Active | false |
30219 | Multiple urine analyte IVD, control |
A material which is used to verify the performance of a number of assays intended to be used for the qualitative and/or semi-quantitative screening of urine for multiple analytes.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JJW | Urinalysis Controls (Assayed And Unassayed) |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 2 and 8 Degrees Celsius |
Handling Environment Temperature: between 18 and 25 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
17d6d8dd-2242-4b35-a7ee-6a89bfc52b5c
October 29, 2018
1
September 26, 2018
October 29, 2018
1
September 26, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
(310) 536-0006
sales@quantimetrix.com