DEVICE: VITEK® 2 AST-GP75 (03573026530679)
Device Identifier (DI) Information
VITEK® 2 AST-GP75
VITEK® 2 AST-GP75
In Commercial Distribution
BIOMERIEUX , INC.
VITEK® 2 AST-GP75
In Commercial Distribution
BIOMERIEUX , INC.
VITEK ® 2 Gram Positive Susceptibility Card is intended for use with the VITEK 2 to determine susceptibility of Staphylococcus spp., Enterococcus spp., & S. agalactiae
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
58605 | General-microorganism antimicrobial susceptibility culture medium IVD |
A non-selective culture medium intended to be used to perform diagnostic antimicrobial susceptibility testing on general microorganisms isolated from a clinical specimen.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LON | System, Test, Automated, Antimicrobial Susceptibility, Short Incubation |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K032399 | 000 |
K032766 | 000 |
K050976 | 000 |
K053097 | 000 |
K072668 | 000 |
K072695 | 000 |
K080201 | 000 |
K091126 | 000 |
K093076 | 000 |
K122547 | 000 |
N50510 | 085 |
N50510 | 101 |
N50510 | 102 |
N50510 | 106 |
N50510 | 108 |
N50510 | 111 |
N50510 | 113 |
N50510 | 116 |
N50510 | 117 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 2 and 8 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
350ca34d-6853-4da7-b331-88f98d4b56c1
May 11, 2022
4
January 09, 2017
May 11, 2022
4
January 09, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
03573026437183 | 20 | 03573026530679 | In Commercial Distribution |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined