DEVICE: OCT500 (03615020000489)

Device Identifier (DI) Information

OCT500
OCT2JT
In Commercial Distribution

ESSILOR INTERNATIONAL
03615020000489
GS1

1
277373213 *Terms of Use
3D Optical Coherence Tomography OCT500 is a non-contact, high-resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional and three dimensional imaging, and measurement of posterior ocular structures, including the retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, ganglion cell complex, macula, optic nerve head. It is also indicated for in-vivo viewing, axial cross-sectional and three dimensional imaging of anterior ocular structures, including the cornea. The instrument is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, agerelated macular degeneration, and glaucoma.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46799 Retinal optical coherence tomography system
An assembly of devices that uses a broad-bandwidth light beam aimed into the eye for in vivo tomographic imaging and measurement of the retina, the retinal nerve fibre layer (its thickness), and optic disk in order to diagnose and manage retinal diseases. Reflected light is picked up by a detector that converts it into electrical signals using a computer and dedicated software, providing cross-sectional images of the retina or three-dimensional (3-D) volume scans. Optical coherence tomography (OCT) is used for visualizing the area/location of retinal-thickness abnormalities, macular holes or oedema, atrophy associated with degenerative diseases, glaucoma, and other retinal pathologies.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OBO Tomography, Optical Coherence
HKI Camera, Ophthalmic, Ac-Powered
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Temperature: between -20 and 50 Degrees Celsius
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 10 and 95 Percent (%) Relative Humidity
Handling Environment Temperature: between -40 and 70 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

d167f846-7e1e-4d99-ba2c-e1e858883177
March 31, 2020
1
March 23, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+33172947322
qualite.instruments@essilor.fr
CLOSE