DEVICE: ABLATHERM FUSION (03661690000199)

Device Identifier (DI) Information

ABLATHERM FUSION
EDP 900800
Not in Commercial Distribution

EDAP-TMS FRANCE
03661690000199
GS1
December 31, 2019
1
383113362 *Terms of Use
The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The system consists of the following main sub-assemblies: Therapy Control Module, Treatment Module, Endorectal Probe, and consumable Ablapak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
11248 Physical therapy ultrasound system
An assembly of devices designed to produce and deliver ultrasonic waves that penetrate tissues and produce both thermal and nonthermal (e.g., mechanical and cavitation) effects to treat pain (e.g., muscle, tendon, joint) and as an aid in the healing of soft-tissue injuries (e.g., ulcerations, bursitis). It typically consists of a radio-frequency (RF) generator (frequencies from one to three megahertz are typical), a cable that transmits the RF energy to the applicator, and an applicator including a piezoelectric transducer that applies the ultrasonic energy to the patient's tissues through the skin.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
PLP High Intensity Ultrasound System For Prostate Tissue Ablation
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

3438fee6-3b45-4850-bb2a-682e3a44ad6c
December 11, 2024
5
February 23, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
512 832-7956
contact@edap-usa.com
CLOSE