DEVICE: Scleral buckling device, non-bioabsorbable (03760087121421)
Device Identifier (DI) Information
Scleral buckling device, non-bioabsorbable
BICONVEX TIRE 9 TYPE 287
In Commercial Distribution
S5.2315U
FCI S A S FCI 20 22
BICONVEX TIRE 9 TYPE 287
In Commercial Distribution
S5.2315U
FCI S A S FCI 20 22
A sterile, non-bioabsorbable device intended to be implanted for intrascleral and episcleral buckling for the surgical treatment of retinal detachment. It is typically a moulded solid silicone or silicone sponge device available in a variety of shapes and sizes that is used to compress the retina long-term (up to months) to support its reattachment following the operative treatment of severe retinal detachment. This device, also known as a scleral buckling component, will occupy the intraocular space to provide compression against the retina so that it can reattach. It is typically removed after a period of time depending upon the clinical findings.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
42545 | Scleral buckling device, non-bioabsorbable |
A non-bioabsorbable device intended to be implanted for intrascleral and episcleral buckling for the surgical treatment of retinal detachment. It is typically a moulded solid silicone or silicone sponge device available in a variety of shapes and sizes that is used to compress the retina long-term (up to months) to support its reattachment following the operative treatment of severe retinal detachment. This device, also known as a scleral buckling component, will occupy the intraocular space to provide compression against the retina so that it can reattach. It is typically removed after a period of time depending upon the clinical findings.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HQX | Implant, Orbital, Extra-Ocular |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Width: 7 Millimeter |
Outer Diameter: 31.28 Millimeter |
Device Record Status
d29cfe0e-ddd5-4f91-a9a5-5c97f7ee4c6a
December 22, 2021
2
March 06, 2020
December 22, 2021
2
March 06, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
53760087121426