DEVICE: RUSCH (04026704319558)

Device Identifier (DI) Information

RUSCH
IPN042739
In Commercial Distribution
170060
TELEFLEX INCORPORATED
04026704319558
GS1

1
002348191 *Terms of Use
SLICK SET CUFFED STERILE
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46967 Basic endotracheal tube, single-use
A hollow cylinder inserted orally or nasally into the trachea to provide an unobstructed airway to convey gases and vapours to and from the lungs during anaesthesia, resuscitation, and other situations where the patient is not properly ventilated; it does not include an antimicrobial agent(s). The device may: 1) be packaged with a connector that will attach to a breathing circuit or manual resuscitator; 2) have a distal inflatable cuff to seal against the tracheal wall; 3) be radiopaque; and 4) have a built-in pilot balloon for cuff pressure monitoring. It is available in various diameters and lengths for adult and paediatric patients. This is a single-use device.
Active false
37469 Artificial airway stylet, single-use
A long stiffening wire/rod designed for insertion within the lumen of an artificial airway tube (e.g., endotracheal tube, bronchial tube) to stiffen and/or maintain the shape of the tube to facilitate introduction (intubation). It is designed to be slightly shorter than the tube to avoid damage to the airway during passage, and is withdrawn after intubation has been completed. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
BTR Tube, tracheal (w/wo connector)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K780900 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Lumen/Inner Diameter: 6 Millimeter
Height: 24 Millimeter
Width: 35 Millimeter
Length: 300 Millimeter
CLOSE

Device Record Status

b9c706da-a2b6-4566-8553-bd7c4c3166f9
July 19, 2023
7
October 16, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
24026704319552 10 04026704319558 In Commercial Distribution Box
44026704319556 10 24026704319552 In Commercial Distribution Case
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
+1(919)544-8000
CS@TELEFLEX.COM
CLOSE