DEVICE: B.BRAUN (04046964091728)
Device Identifier (DI) Information
B.BRAUN
7102233
In Commercial Distribution
7102233
B.Braun Avitum AG
7102233
In Commercial Distribution
7102233
B.Braun Avitum AG
Adimea™ Dialysis Measurement System (Kt/V) for Dialog+®
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| No | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 58130 | Haemodialysis system, institutional |
An assembly of mains electricity (AC-powered) devices intended to be used to perform patient haemodialysis, a treatment whereby extracorporeal blood is passed through a filter to allow for the removal of toxins and/or the replacement of electrolytes, by trained professionals in a healthcare facility. The system functions with dialysate solution and a haemodialysis dialyser (haemodialyzer) for the transfer of substances by diffusion, osmosis and ultrafiltration. It typically includes a pump and tubing to circulate blood through the haemodialysis dialyser, a solution mixer to prepare the dialysate, a monitor with system controls, and other dedicated components.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| KDI | Dialyzer, high permeability with or without sealed dialysate system |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K083460 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Handling Environment Humidity: between 15 and 70 Percent (%) Relative Humidity |
| Handling Environment Temperature: between 15 and 35 Degrees Celsius |
| Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
| Storage Environment Temperature: between -20 and 60 Degrees Celsius |
| Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
| Storage Environment Humidity: between 15 and 80 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
e21919ed-d7e1-4701-b7c5-087eab7b301c
December 18, 2020
8
August 09, 2015
December 18, 2020
8
August 09, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
04046963686789